KOMPONEN DAN PRODUK FOAM SYSTEM

Bladder Tank

  • Capacity: 53 Gal. to 4000 Gal. (200 L to 15,000 L)
  • Foam Proportioners: 50 NB to 200 NB
  • Wide Flow Range: 75 LPM to 30,000 LPM
  • Foam Vessel: Carbon Steel / Stainless Steel
  • Bladder: Nylon Reinforced Nitrile (BUNA-N)
  • Designed as per ASME Sec. VIII DivI 1
  • Rated Pressure: 12 BAR (175 psi)
  • Approvals – UL Listed, CE marked
FOAM CHAMBER

  • Size: 50 NB, 65 NB, 80 NB & 100 NB
  • Flow range from 66 LPM to 2,838 LPM
  • Carbon Steel & Stainless Steel Construction
  • Woking Pressure:  2.1 BAR – 7 BAR
  • Glass/Acrylic Vapour Seal
  • Flanged End Connection
  • Approvals – UL Listed
 
FOAM MAKER  

  • Size: 50 NB, 65 NB & 80 NB
  • Flow Range from 66 LPM to 1,476 LPM
  • Carbon Steel & Stainless Steel Construction
  • Working Pressure: 2.1 BAR – 7 BAR
  • Flanged End Connection
  • Approvals – UL Listed
 
FOAM DEFLECTOR

  • Size: 80 NB, 100 NB, 150 NB & 200 NB
  • Carbon Steel & Stainless-Steel Construction
  • Compatible with Flanges: ANSI B 16.5, 150 #
  • Used with foam chamber for fixed roof tanks
  • Approvals – UL Listed
 
FOAM POURER

  • Size: 80 NB, 100 NB & 150 NB
  • Carbon Steel & Stainless-Steel Construction
  • Compatible with Flanges: ANSI B 16.5, 150 #
  • Used with foam maker for floating roof tanks
  • Approvals – UL Listed

FIRETECH AFFF 1%, 3%, 6% Aqueous Film Forming Foam, +35 F minimum storage and use temperature. Hydrocarbon fuels only.FIRETECH FP 3%, 6%, +35 F minimum storage and use temperature. Hydrocarbon fuels only.FIRETECH FFFP 3%, 6%, +20 F min storage and use temperature. Hydrocarbon fuels only.FIRETECH FREEZE PROTECT AFFF 3%, -20 F min storage and use temperature. Hydrocarbon fuels only.FIRETECH AR-AFFF 1×3%, 3×3%, 3×6%, +35 F min storage and use temperature. For Hydrocarbon fuels and Polar solvent fuels.

  •       Fluorine Free SFFF & AR-SFFF 3%
  •       High Expansion Foam Concentrate 2%, 3%
  •       AFFF 1%, 3%, 6%
  •       AR-AFFF 1/3, 3/3, 3/6
  •       FLUORO PROTEIN FOAM 3 %, 6%
  •       FFFP 3%, 6%
  •       AR-FP 3/3, 3/6
Medium Velocity Water Spray Nozzles

  • End connection: 15 NB (1/2″)
  • Material: Brass, Brass with Nickel Chrome finish, Ni-Al Bronze, Stainless Steel (SS 304 / SS 316)
  • K factor (metric): 18, 22, 30, 35, 41, 51, 64, 79, 91 and 102
  • Discharge angle (degrees): 90, 120, 140
  • Approvals – UL Listed
 
High Velocity Water Spray Nozzles

  • End connection: 20 NB (3/4″)
  • Material: Brass, Brass with Nickel Chrome finish, Stainless Steel
  • K factor (Metric) x Discharge angle (Degrees): 18 x 75, 22 x 80, 26 x 90 and 32 x 100
  • Discharge angle (degrees): 90, 120, 140
 
Revolving Nozzle

  • Gun metal construction
  • K factor, Metric (US): 700 (49), 800 (56) 900 (63) & 1000 (70)
  • End connection: 100 NB (4″)
  • MISI Flange as per ANSI B16.5, 150# 
 
Tank Cooling Nozzle

Water curtain nozzle is an open orifice and non-automatic spray nozzle. Nozzle is designed for use in fixed water spray fire protection systems, especially for protection of fuel storage tanks. Tank Cooling Nozzle is typically mounted in upright position at a distance from the exterior wall of the tank for cooling of the tank. In case of fire in the vicinity of the tank it prevents the tank from absorbing the heat radiation. 

Firetech water curtain nozzle are available in size 15NB and 25NB. The material of construction is stainless steel.

 
Jumbo Water Curtain

Jumbo water curtain nozzle produces a flat semicircular curtain of water projecting upward for radiant heat protection.

 
Air Aspirating Foam Spray Nozzle

Foam/Water nozzles are open, air aspirating discharge heads manufactured and designed for installation as part of an engineered fire protection system. Firetech foam water nozzles are designed for applications where a low expansion foam application is needed followed by a period of water cooling. Construction: Stainless Steel 316
 
End connection: 15 NB (1/2″)
Material: Stainless Steel 316
K factor (metric): 40 and 42
Installation: Pendent Type
 
Non Air Aspirating Foam Spray Nozzle

  • End connection: 15 NB (1/2″)
  • Material: Stainless Steel 316
  • K factor (metric): 43 and 79
  • Discharge angle (degrees): 140
  • Approvals – UL Listed
HVLR Foam Monitor Variable Flow Type

  • Variable Flow: 1000-1500-2000 GPM
  • Size: 150 NB (6″) flanged inlet
  • Stainless Steel waterway
  • Gear for horizontal and vertical movement
    • 360° continuous horizontal rotation
    • +90°, – 45º- vertical Rotation
  • Approvals – UL Listed
 
Water Cum Foam Monitor

  • Capacity: 750 GPM
  • Size: 100 (4″) flanged inlet
  • Stainless Steel waterway
  • Gear for horizontal and vertical movement 
    • 360° – Continuous horizontal rotation
    • +90°, -45° – Vertical Rotation
  • Horizontal Range with water @ 30 Deg. 60 Mtr
  • Approvals – UL Listed
 
Water Monitor

  • Fixed Flow
  • Available Flow: 1750 / 2580 / 3500 LPM
  • Barrel Diameter Size: 63 NB, 80 NB & 100 NB
  • Inlet Flange Size: 100 NB
  • Barrel Construction: Carbon Steel / SS 304 / SS 316
  • Nozzle Construction: Aluminium / SS 304 / SS 316
  • Approvals – ISI Approved